/* File: comm.c Desc: This file implements the actual transmission portion of the "ok to power me down" message to the remote power cycling black box. It's been sepatated into a separate file so that it may be replaced by any other comm mechanism desired. (including none or non serial mode at all) $Id: comm.c,v 1.3 2005/11/07 11:15:17 gleixner Exp $ $Log: comm.c,v $ Revision 1.3 2005/11/07 11:15:17 gleixner [MTD / JFFS2] Clean up trailing white spaces Revision 1.2 2001/06/21 23:07:18 dwmw2 Initial import to MTD CVS Revision 1.1 2001/06/08 22:26:05 vipin Split the modbus comm part of the program (that sends the ok to pwr me down message) into another file "comm.c" */ #include #include #include /* This is the routine that forms and sends the "ok to pwr me down" message to the remote power cycling "black box". */ int do_pwr_dn(int fd, int cycleCnt) { char buf[200]; sprintf(buf, "ok to power me down!\nCount = %i\n", cycleCnt); if(write(fd, buf, strlen(buf)) < strlen(buf)) { perror("write error"); return -1; } return 0; }